TAG-8000 Wireless High Voltage Phase Tester

TAG-8000 Wireless High Voltage Phase Tester is mainly used in phase check and phase sequence check of power lines and substations.

TAG-8000 Wireless High Voltage Phase Tester


Brief Introduction:

TAG-8000 HV phase tester, used in power lines, phase tests and phase sequence tests for substations, with functions of phase testing, phase sequence testing, electrical inspection.

With strong anti-interference, in line with (EMC) standards, adapt to a variety of electromagnetic interference occasions.

High voltage phase signal will be taken out by the collector, discharge directly after treatment. Received by instrument and compare the phase, and identify the results, real-time display difference of phase angle and vector.

This product use wireless transmission technology, it is safe, reliable, fast and accurate.


Main Features:

Measurement voltage: 10-500kV (according customer order)

Accuracy: self-calibration error≤±3°

Sampling speed: 10 times/S

Time setting: Easy for users to browse, view historical data

Backlight time settings: on, off, set within 0-999 seconds

Automatic shutdown settings: Never, within 0-999 minutes setting

In-phase: ≤20°is in-phase, (phase threshold within 0-900, system default value is 20)

Out-phase: >20°is out-phase, (phase threshold within 0-900, system default value is 20) 

Field calibration function: field calibration for measured lead to ensure the accuracy of the phase angle

Handset detectors and X, Y detectors transmission distance: X≤150m, Y≤150m

Multi-mode design, applicability, safer, and more convenient

Unique interactive interface, simple operation

FCC antenna design, signal stronger, easier to penetrate walls , doors or obstacles blocking

Double shielding, strong anti-interference, in full compliance with EMC standards

Charts and data display, easier to read

Qualitative measurement: sound and light signal display

Quantitative measurements: real-time display of phase angle difference, error≤5°

Phase sequence check: Shun phase sequence, reverse phase sequence (120, 240°)


Main Parameters:

Measurement voltage

10V-500kV (customized)

Power

Handset: #5 AA Alkaline batteries:2 (1.5V)

X, Y detector : #7 AA Alkaline batteries: 3 (1.5V)

Wireless transmission distance

Stadia distance 150M

In-phase

Phase angle shift≤20°( threshold 0-90, self setting)

Out-phase

Phase angle shift20° ( threshold 0-90, self setting)

Display Accuracy

Quantitative measurements≤5°

Phase angle resolution

Phase sequence measurement

Checked by : 120°clockwise  /240°Counterclockwise

Display

LCD

Operating temperature

-35---+50

Storage temperature

-40---+55

Relative humidity

≤95 RH

Handset set

0.31 kg

X detector

0.16 kg

Y detector

0.16 kg

 