XDC Battery Capacity Load Bank Discharge Tester

It can serve as discharge loads and realize discharge with the set constant currents by means of continuous control over discharge currents.

XDC Battery Capacity Load Bank Discharge Tester


Introduction:

XDC Battery Capacity Load Bank Discharge Tester can serve as discharge loads and realize discharge with the set constant currents by means of continuous control over discharge currents.

When the voltage of a battery pack or a single battery is lower than the limit of voltage, or the set discharge duration or reach the set discharge capacity during discharge, 

the tester will automatically stop discharge and record the real-time data of all valuable and continuous process.

The voltage information of single batteries monitored by the tester is subject to wireless repeater access that is simple, secure and accurate.

With strong software, the setup and data treatment can be done through the touch screen. The process data can be read and upload to computer for analysis.


Specifications:

Applicable battery

Lead-acid   battery

Output voltage

DC10-300V

Output current

10~19V:   0~50A

19~180V:   0~100A

180~300V:   0~50A

Operating mode

Use   the tester independently or with a constant-current module

Protection performance

Input   terminal overvoltage protection, prompts on the LCD;

Reverse   polarity protection, buzzer alarm;

Overcurrent   protection, prompts on the LCD;

85   overheat protection, prompts on the LCD, buzzer alarm.

Single battery voltage   acquisition

The   433RF wireless module supports a communication distance longer than 100 m and   monitoring for single battery voltages of 2V, 4V, 6V and 12V. If the total   voltage is not beyond the set value, each battery pack will have an unlimited   single battery quantity and can monitor one to sixteen RF wireless monitoring   modules at the same time.

One   RF wireless monitoring module can monitor 12 single batteries at the same   time.

Control accuracy

Discharge current: ≤±1%; battery pack’s terminal   voltage: ≤ ±0.5%; single battery voltage: ≤±0.1%

Communication with PC

RS485 interface

Data storage

2Gbit FLASH

Operating conditions

Cooling

Forced air cooling

Temperature

Operating temperature: -5~50; storage temperature: -40~70

Humidity

Relative humidity: 0~90% (40±2)

Noise

60dB

Operating power supply

Voltage

220V   AC (–20%~+30%); frequency: 45~65Hz;

Withstand voltage test

Input--casing:   2200Vdc 1min

Input--output:   2200Vdc 1min

Output--casing:   700Vdc 1min

Safety

Compliance   line with EN610950

Wiring

AC output

Male   socket in line with the applicable national standard, applicable to 1~1.5mm2   cable

DC output

25mm2   cable quick plug (red: positive; black: negative)