It is designed and manufactured in accordance with DIN 53438 & ISO 11925-2 standard.
SIT Single Flame Source ISO 11925-2 Building Products Ignitability Test Chamber
Introduction:
SIT Single Flame Source ISO11925-2 Ignitability Test Chamber is designed and manufactured in accordance with DIN 53438 & ISO 11925-2 standard.
SIT Single Flame Source ISO11925-2 Ignitability Test Chamber uses the German Kleinbrenner principle to determine the combustion properties of building materials under direct impact from a small vertical flame. It is applicable to building material categories of B, C, D, E, Bfl, Cfl, Dfl and Efl testing.
SIT Single Flame Source ISO11925-2 Ignitability Test Chamber also meets DIN 4102-Part 1-Class B2 test requirements.
Standards:
DIN: DIN 53438
ISO: ISO 11925-2
EN: EN 13501
IEC: IEC 61730-2:2016
Application Field:
Building Materials;
Rail;
Features:
The combustion chamber is made from corrosion resistant stainless steel, to maximize operating life.
It has large front and side doors for easy access. These are glazed with toughened glass for full view of the specimen during a test.
An extensively adjustable burner assembly, mounted on runners, to enable the small premixed flame to be tilted at an angle of 45degree to the specimen and offered to it in one fluid movement.
Specimen holder capable of housing the specimens up to and including 60 mm thick.
A fully adjustable specimen support frame facilitating lateral movement of the specimen holder so that the flame can be applied either at the specimen centre position, or at laterally spaced points.
Options available:
Multilayer specimen holder
Loose fill specimen holder
Anemometer 0-10 m/s range
Timing device with 0.2 sec divisions
Pressure reducing valve: Between 10 kPa and 50 kPa
Parameters:
No. | Item Name | SIT Single Flame Source ISO11925-2 Ignitability Test Chamber |
1 | Dimension | 850 mm (W) X 450 mm (D) X 800 mm (H) |
2 | Weight | 24kg |
3 | Power supply | 110V AC 60Hz / 230V AC 50Hz, 10A |
4 | Ambient temperature | Operating 10°C to 35°C |
5 | Gas supply | Propane with a minimum purity of 95% |